Select Page

Hour Meter doesn’t work

If the red light on the hour meter is flashing when gas is being produced, the inner wiring is fine and if the hour meter is not working it needs replaced. If the hour meter red light is NOT flashing when gas is being produced, we go into the machine (take the hood...

White powder around base of Tower Cap.

That would be lye and indicates that you have a tiny gas leak there.I’d love it if you’d send me a picture of it for my (eventually) trouble-shooting guide.After the picture, remove the Tower Cap, clean the lye off (wipe first, then rinse several...

Gas leak

1. Is the green gas production light on?  Yes = proceed. No = get in touch with meSince your green light stays on and does not flicker, we’ve eliminated the possibility of a partially plugged gas out hose.So the issues we’ll now test for are:1. Not enough gas...

No or Low gas production

To diagnose the problem there are a series of questions.  The next question depends on the answer to the previous question so I can only ask one at a time.  Please remember that I’m diagnosing ‘blind’ thus depend on you to be my hands and eyes.  More information is...

Lubrication or Replacing the Cooling Fan

First, as long as the fan is spinning ‘noise’ doesn’t matter to it’s function.But I can understand that it is annoying.Most fans do not need to be replaced, just lubricated.We recommend a product called Fluid...

Tower Cap rubber gasket leaking

We tried making a gasket in the base of the Tower Cap, because we thought it’d be simpler if we could make it work.  It does work for a time, but eventually it does get chewed up and stops sealing.Once that gasket is gone, it’s gone and you revert to the original form...